Innovate-motorsports SCG-1 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Urządzenia pomiarowe Innovate-motorsports SCG-1. Innovate Motorsports SCG-1 User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 19
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
SCG-1
User Manual
Warning!
The Oxygen Sensor used in this device gets very hot in operation.
Do not touch a hot sensor. Do not let a hot sensor touch a combustible surface. Do not use the
sensor with or near flammable liquids or gases. Failure to heed these warnings may result in
severe burns, explosions, fires, or other dangerous events.
1 SCG-1 ......................................................................................................2
1.1 Changing the SCG-1’s gauge face and/or bezel................................3
2 Installation................................................................................................4
2.1 Wiring .................................................................................................4
2.1.1 Single Innovate Device Relay Wiring Instructions.....................5
2.2 Gauge Mounting and Routing ............................................................6
2.3 Solenoid Installation...........................................................................6
2.3.1 Internal Wastegate.....................................................................6
2.3.2 External Wastegate ...................................................................7
2.4 MAP sensor........................................................................................7
2.5 Wideband Oxygen Sensor Setup.......................................................7
2.5.1 Oxygen Sensor Placement........................................................7
2.5.2 Sensor Calibration.....................................................................9
2.5.3 Calibration Schedule..................................................................9
3 Boost Controller Setup...........................................................................10
3.1 Entering Setup Configuration...........................................................10
3.1.1 Configuration using SCG-1’s interface buttons .......................10
3.1.2 Configuration using the LM Programmer software..................10
3.2 Display Settings (Gauge Abbreviations) ..........................................11
3.3 RPM Settings (Gauge Abbreviations)..............................................11
3.4 Solenoid Settings (Gauge Abbreviations)........................................11
4 Logworks 3 & LM Programmer Software Package................................13
4.1 Download and Install the Logworks 3 Software...............................13
4.2 LM Programmer................................................................................14
4.2.1 Programming Analog Output...................................................14
4.2.2 Advanced Analog Output Programming..................................15
4.2.3 Updating the Firmware ............................................................15
4.3 Logging data from your SCG-1 with LogWorks................................16
Appendix A: Limited Warranty.......................................................................17
Appendix B: SCG-1 Error Codes and Troubleshooting Tips.........................18
Przeglądanie stron 0
1 2 3 4 5 6 ... 18 19

Podsumowanie treści

Strona 1

SCG-1 User Manual Warning! The Oxygen Sensor used in this device gets very hot in operation. Do not touch a hot sensor. Do not let a hot sen

Strona 2 - 1 SCG-1

10 Race Application - Calibrate before first installation of new sensor - Calibrate once per race weekend 3 Boost Controller Setup 3.1 Entering Se

Strona 3

11 Once you have completed your desired changes, press the Program button on the lower right on the software application. You will know that the SCG-

Strona 4 - 2 Installation

12 Tuning Tip: Start small and work up. Do not increase Wastegate Duty if Boost/AFR cuts occur. Remedy Boost/AFR cuts before increasing Wastegate Dut

Strona 5

13 defined lean A/F that will trigger the safety cut. When the Boost Cut by AFR is triggered, the SCG-1 will display “O2 Cut” on the upper right han

Strona 6

14 4. The installer will start, follow the prompts to install the software. 5. Once the software has been installed, the LogWorks software, LM Pr

Strona 7

15 By selecting the ‘use Air-Fuel-Ratio’ button you can change the displayed unit of measure for mixture by AFR instead of Lambda. This does not cha

Strona 8

16 1. Connect the SCG-1 to the computer and launch LM Programmer. 2. Once connected, LM Programmer will display the current version of the firmwa

Strona 9

17 Appendix A: Limited Warranty LIMITED WARRANTY Innovate stands behind the quality of its products. Innovate makes the following warran

Strona 10 - 3 Boost Controller Setup

18 MERCHANTABILITY, NONINFRINGEMENT, AND FITNESS FOR A PARTICULAR PURPOSE, AND THE LIABILITY OF INNOVATE, IF ANY, FOR DAMAGES RELATING TO ANY ALLEGED

Strona 11

19 4. Replace sensor. Error 9 Supply Voltage too low Supply voltage too low for sensor regulation 1. Verify you have 12V at your power source and the

Strona 12

2 1 SCG-1 The SCG-1 is a boost solenoid controller gauge with an integrated wideband AFR (lambda) control. The SCG-1 also has advanced safety boo

Strona 13

3 3. Interface Buttons - Pressing either the left or right interface buttons will allow you to cycle through the 4 different display modes. - F

Strona 14

4 3. Configure the gauge as desired by changing the gauge face and/or bezel. 4. Make sure every piece is positioned correctly using the locati

Strona 15

5 3 Connect the WHITE wire to a headlight power wire (a wire that goes hot with 12V when the headlights are on)). This enables the display to dim for

Strona 16

6 2.2 Gauge Mounting and Routing The SCG-1 gauge fits in any standard 2 1/16” (52mm) gauge pod. Mounting of the gauge should be done in such a mann

Strona 17

7 2.3.2 External Wastegate 2.4 MAP sensor 1. The MAP sensor MUST be installed with the hose fitting facing down. It is very important that the se

Strona 18

8 accurate readings. Using a bung is the preferred method for mounting the oxygen sensor in all applications. - Weld the bung at least 24 inches a

Strona 19

9 2.5.2 Sensor Calibration Once the unit has been wired and a suitable location has been found for both the gauge and the sensor. it is time to perfo

Komentarze do niniejszej Instrukcji

Brak uwag