Innovate-motorsports LMA-3 Instrukcja Użytkownika Strona 26

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 30
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 25
- 26 -
You can enter any frequency between 10 Hz and 15000 Hz as full scale frequency. LMA-3
measures the frequency with a resolution of 0.1 % of the full scale frequency specified. So in
LogWorks 0 Hz is always 0 Volt, and the full-scale frequency is equivalent to 5 Volt.
This functionality is also available for Inputs 4 and 5.
11.5.3 Measuring Speed
Select the Speed sensing function in the topmost drop-down list. The center section of the
window changes to:
With the radio buttons you can select to use metric (km/h) or US (mph) units. In the left drop-
down list you select the max speed to be measured. The LMA-3 measures the speed with a
resolution of 0.1 % of the selected max speed.
In the right edit box you enter the pulses per mile the speed sensor produces. Speed sensors are
typically pulse sensors mounted either on the drive-shaft or wheel. To calculate the pulses per
mile (or km/h) click on the calculate button: